Datasheet File OCR Text: |
Dual Relays 25-40Amp * 120/240, 480 Vac * AC OUTPUT * Zero Voltage and Random Turn-On Swi tching * SCR Output * Industry Standard Package * Panel M ount Two totally independent AC output relays come in a single standard panelmount package. Utilizing an AC switch output with internal snubber, relays provide greater protection against false triggering. Model choices include zerovoltage or random turn-on (phase controllable) switching. Manufactured in Crydom's ISO 9001 Certified facility for optimum product performance and reliability. H12D4825D H12D4825DE H12D4840D H12D4840DE MODEL NUMBERS OUTPUT SPECIFICATIONS Operating Voltage (47-63 Hz) [Vrms] Load Current Range [Arms] Transient Overvoltage [Vpk] Max. Surge Current, (16.6ms) [Apk] Max. On-State Voltage Drop @ Rated Current [Vpk] Thermal Resistance Junction to Case (RJC) [uC/W] Maximum I2 t for Fusing, (8.3 msec.) [A2sec] Max. Off-State Leakage Current @ Rated Voltage [mArms] Min. Off-State dv/dt @ Max. Rated Voltage [V/sec] Max. Turn-On Time Max. Turn-Off Time Power Factor (Min.) with Max. Load D2425D D2425DE D2440D D2440DE 24-280 .15-25 600 250 1.6 1.02 260 10 500 1/2 cycle 1/2 cycle 0.5 24-280 .15-40 600 625 1.6 .63 1620 10 500 1/2 cycle 1/2 cycle 0.5 48-530 .15-25 1200 250 1.6 1.02 260 10 500 1/2 cycle 1/2 cycle 0.5 48-530 .15-40 1200 625 1.6 .63 1620 10 500 1/2 cycle 1/2 cycle 0.5 INPUT SPECIFICATIONS Control Voltage Range Max. Turn-On Voltage Min. Turn-Off Voltage Nominal Input Impedance Typical Input Current @ 5Vdc (@ 24Vdc for E-Suffix) D24XXD 4-15Vdc 4.0 Vdc 1.0 Vdc 300 Ohms 13mA H12D48XXD 4-15Vdc 4.0 Vdc 1.0 Vdc 240 Ohms 13mA E-SUFFIX 15-32Vdc 15 Vdc 1.0 Vdc 1500 Ohms 15mA GENERAL NOTES (c) 2003 CRYDOM CORP, Specifications subject to change without notice. All parameters at 25C and per section unless otherwise specified. Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1 Heat sinking required, for derating curves see page 2. Turn-on time for random turn-on (-10) versions is 0.1 msec. w w FastFax Document No. 165 DUAL. Rev. 111203 PAGE 1 OF 2 w .d ee sh ta a u. t4 om c Crydom Heat Sinks offer excellent thermal management and are perfectly matched to the load current ratings of Crydom panel mount relays. Request Crydom's Heat Sink specification sheet for all the details. For recommended applications and more information contact: USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540 Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154 Email: sales@crydom.com WEB SITE: http://www.crydom.com UK: +44 (0)1202 365070 * FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com. GERMANY: +49 (0)180 3000 506 www..com Dual Relays 25-40Amp * 120/240, 480 Vac * AC OUTPUT GENERAL SPECIFICATIONS Dielectric Strength50/60Hz Input/Output/Base Insulation Resistance (Min.) @ 500 Vdc Max. Capacitance Input/Output Ambient Operating Temperature Range Ambient Storage Temperature Range M ECHANICAL SPECIFICATIONS Weight: (typical) 4000 Vrms 109 Ohm 10 pF -40 to 80C -40 to 125C 3.0 oz. (86.5g) Encapsulation: Terminals: 120/240 V MO DEL AVAILABLE OPTIONS -10 Thermally Conductive Epoxy .25' Fastons, .025' Square Pins 480V MO DEL FASTON TERMINAL .250 X .032 (4 PLACES) Random Turn-On, Phase Controllable Example: D2440D-10 15-32Vdc Control Example: H12D4840DE Heat Transfer Pad (Attached) Example: D2440DH MOUNTING HOLE/SLOT 0.17 (4.3) DIA. A2 A1 1.17 (29.7) 1.00 (25.4) B1 B2 120/24OV - 20A .15 (3.8) .250 X .032 FASTON TERMINAL (4 PLACES) MOUNTING HOLE/SLOT .017 (4.3) DIA. 2 PLC'S .55 (14.0) A1 A2 120/24OV - 20A B1 B2 120/24OV - 20A 120/24OV - 20A E 2.30 1.87 (58.4) (47.5) CONTROL A 4-15VDC CONTROL B 4-15VDC 2.30 (58.4) CONTROL 1.87 1.60 (47.5) (40.6) A CONTROL B H .50 (12.7) PIN .025 SQ. .100 CENTERS 4 PLACES .45 (11.4) .85 (21.6) 1.31 (33.2) - + - + .77 (19.6) 1.37 (34.8) 1.80 1.80 (45.7) .187 X .032 FASTON TERMINAL (4 PLACES) .85 (21.6) 1.31 (33.2) All dimensions are in inches (millimeters) 25A 50A LIMIT (2 SECTIONS) CURRENT DERATING CURVES Max Allowable Base Temp. [C] 40A Max Allowable Base Temp. [C] Power Dissipation [W] 0.5C/W 75 85 40 25A LIMIT (1 SECTION) 2.0C/W 1.0C/W Power Dissipation [W] 100 80 60 40 20 0 20 40 40A LIMIT (1 SECTION) 80A LIMIT (2 SECTIONS) 0.5C/W 95 105 20 5.0C/W 90 95 100 105 1.0C/W 2.0C/W 5.0C/W 0 10 20 30 40 50 10 20 30 40 50 60 70 80 Load Current [Arms] Max Ambient Temp. [C] 60 80 100 10 20 30 40 50 60 70 80 Load Current [Arms] Max Ambient Temp. [C] LOAD B 480Vrms 120/240Vrms A2 LOAD A A1 B1 B2 LOAD B 120/240Vrms LOAD A 480Vrms 240V Model W IRING DIAGRAM S -- B CONTROL + B CONTROL -- A CONTROL + A CONTROL A1 A2 B1 B2 480V Model -- A CONTROL + A CONTROL + B CONTROL -- B CONTROL APPROVALS UL E116949 CSA LR81689 (240V only) VDE 5902 UG FastFax Document No. 165 DUAL. Rev. 111203 PAGE 2 OF 2 (c)2003 CRYDOM CORP, Specifications subject to change without notice. For recommended applications and more information contact: USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540 Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154 Email: sales@crydom.com WEB SITE: http://www.crydom.com UK: +44 (0)1202 365070 * FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com. GERMANY: +49 (0)180 3000 506 |
Price & Availability of H12D4825DE |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |